Lubricating oils used in steam gas turbine systems usually faced with severe contamination of various of water contents and mechanical impurities. KLEANOIL VTP Turbine Oil Purifier is designed for oil recondition, removing contaminants form turbine oil, prevent sludge accumulation, which in turn ensure the safe operation of the turbine system.
The oil conditioning system's coalescence separation unit can effectively remove free water content , while vacuum dehydration process expel dissolved moisture down to 50 ppm.
Optional:
Item | Unit | VTP-10 | VTP-20 | VTP-30 | VTP-50 | VTP-100 | VTP-150 | VTP-200 | VTP-300 |
Flow Rate | L/min | 10 | 20 | 30 | 50 | 100 | 150 | 200 | 300 |
Vacuum Degree | MPa |
-0.06 ~ -0.095 |
|||||||
Working Pressure | MPa |
≤0.5 |
|||||||
Temperature | ℃ |
20 ~ 80 |
|||||||
Water Content | PPM |
≤50 |
|||||||
Particulates | um |
≤3 |
|||||||
Power Supply |
∽50Hz 380V(customizable) |
||||||||
Working Noise | dB(A) | ≤75 | ≤75 | ≤75 | ≤78 | ≤78 | ≤78 | ≤80 | ≤82 |
Heating power | kW | 19 | 24 | 30 | 40 | 60 | 90 | 120 | 150 |
Total power | KW | 21 | 26.5 | 33 | 44 | 65 | 96 | 127 | 159 |
Inlet/outlet caliber | mm | 25 | 25 | 25 | 32 | 42 | 50 | 50 | 60 |
Weight | Kg | 450 | 550 | 650 | 770 | 900 | 1050 | 1200 | 1500 |
Note: The technical data are for reference only. We reserve the right to make changes in the course of technical development of the product.